Reverberation
Defining, working out and measuring reverb time (RT60, T20, T30, Sabine, Eyring), knowing which RT each use wants, and reading C50/C80 clarity and STI intelligibility.
15-minute lesson · Room acoustics. In the app it ends with a three-level quiz and comes with the matching calculators.
Chop pink noise dead in a room: sound doesn’t stop clean, it dies out. That’s reverberation, the tail of every reflection still circulating. Around 1900, Wallace Sabine defined reverb time: how long level takes to fall 60 dB after the source stops. It’s called RT60, T60 or TR. It’s quoted per octave band (125 Hz to 4 kHz at least), since no room reverberates bass and highs alike.
Measuring without 60 dB: T20 and T30
In a real room, background noise almost always hides 60 dB of decay. So slope is measured over part of the curve and extrapolated. T20: slope between −5 and −25 dB, times 3. T30: between −5 and −35 dB, times 2. Starting at −5 dB skips direct sound and the very first reflections. Headroom matters: ISO 3382 wants the range’s bottom ~10 dB above background noise — at least 35 dB of range for T20, 45 dB for T30. EDT (early decay time) measures slope between 0 and −10 dB, times 6: it tracks the reverb you actually hear during music better.
Sabine’s formula
T = 0.161·V / A A = Σ Sᵢ·αᵢ (V in m³, A in m², T in s)
RT runs with volume and against absorption. A 1,000 m³ room with 161 m² of equivalent absorption has a 1 s RT. Double absorption: 0.5 s. Double volume with the same absorption: 2 s. The 0.161 comes from sound speed (24·ln 10 / c, with c ≈ 343 m/s). In big rooms and up top, air absorbs too: then add a 4·m·V term to A, where m is air’s attenuation coefficient.
Eyring’s formula
Eyring: T = 0.161·V / (−S·ln(1 − ᾱ)), with S total surface and ᾱ = A / S the average coefficient. Sabine assumes a fairly reverberant room. When average absorption tops ~0.2 to 0.3 (studio, heavily treated or full room), Sabine overshoots RT: at ᾱ = 1 it still gives a non-zero RT, which is absurd. Eyring fixes that flaw. Both assume a diffuse field: sound spread everywhere, absorption well spread. A warehouse with all absorption in the ceiling or a very long room breaks that: formulas give an order of magnitude, measurement decides.
The crowd effect
One audience member soaks up roughly 0.4 to 0.5 m² around 500 Hz–1 kHz (less down low), seated or standing, lightly dressed or coated. So 1,000 people add ~450 m² of absorption — as much as a full treatment. That’s why the room sounds drier at showtime than soundcheck. Padded seats shrink the empty/full gap. In a warehouse, 3 p.m. vs 3 a.m. differs hugely.
Which RT for which use?
Speech wants a short RT: each syllable must die before the next. Acoustic music likes a longer RT, binding notes and carrying the orchestra. Amplified music wants a fairly dry room, down low especially, since the PA already brings its own effects. For a mix control room, the EBU targets a nominal RT Tm = 0.25·(V / 100)^(1/3) s, between 0.2 and 0.4 s.
Clarity, definition and intelligibility
| Metric | What it compares | Landmark |
|---|---|---|
| EDT | Slope of the first 10 dB, × 6 | Perceived reverberation |
| T20, T30 | Slope over 20 or 30 dB, extrapolated to 60 dB | The “official” RT |
| C50 (speech) | 10·log(energy of first 50 ms / later energy), in dB | Above 0 dB: clear speech |
| D50 (definition) | Share of energy in the first 50 ms, in % | Above 50%: good for speech |
| C80 (music) | 10·log(energy of first 80 ms / later energy), in dB | Around 0 dB (−2 to +2) often quoted for symphonic; higher for amplified |
| STI (speech transmission index) | 0 to 1: what survives of speech envelope wobbles after reverb and noise (IEC 60268-16); quick STIPA version with a test signal | Above 0.6: good; under 0.45: poor; voice alarm: usually at least 0.50 |
Measuring in practice
- Interrupted-noise method: loud pink noise through an omnidirectional speaker, cut it and record the decay (several averages)
- Impulse-response method: a sine sweep or an impulse (balloon, clapper), then Schroeder backwards integration gives a clean decay curve
- Several source and mic positions, per octave or third-octave band: ISO 3382-1 for performance halls, ISO 3382-2 for ordinary rooms
- Omnidirectional measurement mic, plenty of level above background noise, ventilation and AC noted
- An empty room gives the worst case: always note the state you measured in
- An alarm pistol or bursting balloon easily tops 130 dB(C) peak up close: ear protection for you and everyone present
With REW (or Smaart)
In REW, a sweep measurement gives the impulse response. The RT60 tab shows EDT, T20, T30 and a REW-computed Topt per band; C50, C80 and D50 export. Check the Schroeder curve runs straight into the noise floor, and lengthen the sweep and impulse-response window in big volumes, or the tail gets chopped. In a small room with directional speakers, REW flags that T20 and T30 often undershoot RT: watch Topt. Smaart also offers an impulse-response mode with these metrics.
Practise with
Sources
- ISO 3382-1 : Mesurage des paramètres acoustiques des salles, partie 1 : salles de spectacles — ISO
- ISO 3382-2 : Durée de réverbération des salles ordinaires — ISO
- REW Help : RT60 Graph — John Mulcahy, Room EQ Wizard
- IEC 60268-16 : Évaluation objective de l’intelligibilité de la parole par l’indice de transmission de la parole — IEC
- EBU Tech 3276 : Listening conditions for the assessment of sound programme material — UER / EBU
- Master Handbook of Acoustics — F. Alton Everest, Ken C. Pohlmann (McGraw-Hill)