Sound maths
The technician’s calculation toolkit: powers of 10, logarithms, roots, sine waves, peak and RMS values, octaves and rounding.
15-minute lesson · Maths, power, electronics. In the app it ends with a three-level quiz and comes with the matching calculators.
No need to be a maths whiz to tune a system, but you need a small toolkit: writing very big and very small numbers, turning a ratio into decibels, reading a sine wave, counting in octaves. With these you do most field maths in your head — and you know when the calculator is wrong… or when it’s you.
Powers of 10 and prefixes
| Prefix | Symbol | Factor | Sound example |
|---|---|---|---|
| giga | G | 10⁹ | 1 Gbit/s: a Dante network link |
| mega | M | 10⁶ | 1 MΩ: an active DI input |
| kilo | k | 10³ | 48 kHz, 10 kΩ |
| milli | m | 10⁻³ | 2 mV: a dynamic mic’s output; 20 ms of delay |
| micro | µ | 10⁻⁶ | 20 µPa: hearing threshold; 1 µF |
| nano | n | 10⁻⁹ | 10 nF in a filter |
| pico | p | 10⁻¹² | 100 pF: roughly a metre of cable’s capacitance |
Scientific notation, squares and roots
Write a number as a × 10ⁿ, with a between 1 and 10: 343 m/s = 3.43 × 10² m/s; 0.00002 Pa = 2 × 10⁻⁵ Pa. To multiply, add the exponents; to divide, subtract: 1 kΩ × 1 µF = 10³ × 10⁻⁶ = 10⁻³ s = 1 ms. On the calculator, the EXP (or ×10ˣ) key avoids zero-counting slips: 4.7 nF types as 4.7E-9. Squares: power goes with the square of voltage (P = U² / R), so doubling voltage quadruples power. Back to voltage with the root: 1000 W into 8 Ω needs U = √(1000 × 8) ≈ 89.4 V. Two roots to know: √2 ≈ 1.414 (sine peak and RMS) and √3 ≈ 1.732 (three-phase: 230 × √3 ≈ 400 V). In acoustics, intensity falls with the square of distance: the 1/r² law (see Propagation and SPL).
Logarithms: counting powers of 10
The base-10 logarithm answers “10 to what power?”: log(1000) = 3, log(1) = 0, log(0.01) = −2. It turns multiplications into additions: that’s why the decibel uses it, and why the ear — which hears ratios, not differences — feels at home (see The decibel, painlessly). Landmarks: log 2 ≈ 0.3, hence 10·log 2 ≈ 3 dB (power × 2) and 20·log 2 ≈ 6 dB (voltage × 2); log 3 ≈ 0.48; log 5 ≈ 0.7. To count octaves, use base-2 log: log₂(x) = log(x) / log(2) ≈ 3.32 × log(x). On a log scale, every octave takes equal space: that’s a spectrum analyser’s scale.
log(a × b) = log a + log b log(a / b) = log a − log b log(aⁿ) = n × log a log 2 ≈ 0.301
The sine: amplitude, period, phase
The sine is the base signal: a pure tone, the mains, a 1 kHz test signal. Its amplitude (peak, written Û) is its maximum excursion from zero. Its period T is one cycle’s duration, the inverse of frequency. One full cycle is one trip round a circle: 360°, i.e. 2π radians. Angular frequency ω = 2πf counts radians per second. A delay Δt shifts phase by 360 × f × Δt degrees: 1 ms at 250 Hz is a quarter-turn, 90° (see Frequency, wavelength, phase).
u(t) = Û · sin(ω·t + φ) ω = 2π·f T = 1 / f 180° = π rad φ = 360 × f × Δt
Peak, peak-to-peak, RMS
The RMS (root mean square) value is the DC voltage that would heat a resistor the same. For a sine only, RMS = peak / √2 ≈ 0.707 × peak, and peak-to-peak = 2 × peak. Mains 230 V is RMS: it actually peaks at 325 V, 650 V peak-to-peak. Crest factor compares peak to RMS. Careful: a bargain multimeter only reads right on a sine; on music or noise you need a “true RMS” meter.
| Signal | Peak / RMS | Crest factor |
|---|---|---|
| Square | 1 | 0 dB |
| Sine | √2 ≈ 1.41 | 3 dB |
| Triangle | √3 ≈ 1.73 | 4.8 dB |
| Measurement pink noise | ≈ 4 | ≈ 12 dB |
| Music | 4 to 10 | 12 to 20 dB |
Rule of three, octaves and rounding
- Rule of three: if sound covers 343 m in 1 s, it covers 10 m in 10 / 343 = 0.029 s, i.e. 29 ms. But not everything is proportional: dB, power vs voltage, level vs distance
- Octave = frequency × 2. 1/n-octave fraction: × 2^(1/n). Third-octave: × 1.26; semitone (1/12 octave): × 1.059
- Octaves between f₁ and f₂: log₂(f₂ / f₁). 20 Hz to 20 kHz: about 10 octaves. One decade (× 10) ≈ 3.32 octaves
- Edges of a 1/n-octave band centred on f₀: f₀ × 2^(±1/2n). Third-octave at 1 kHz: 891 to 1122 Hz
- Standardised bands (ISO 266, IEC 61260-1) are worked out base-10 (10^(1/10) ≈ 1.259) and rounded: 1000, 1250, 1600, 2000 Hz. The gap with base 2 is negligible in the field
- Rounding: keep every digit through the maths and round only at the end, to 2–3 significant figures. Convert to SI first (ms → s, kHz → Hz, nF → F), then sanity-check magnitude: 2 s of delay for 10 m means a dropped power of 10
Practise with
Sources
- Brochure sur le SI : le Système international d’unités (9e édition) — BIPM
- ISO 266:1997 — Acoustique, fréquences normales — ISO
- Octave and one-third octave band calculator — Eberhard Sengpiel, sengpielaudio
- What is amplitude? — Eberhard Sengpiel, sengpielaudio
- Handbook for Sound Engineers (5e édition, 2015) — Glen Ballou (dir.), Focal Press