Système Dcalculate, tune, understand

Sound maths

The technician’s calculation toolkit: powers of 10, logarithms, roots, sine waves, peak and RMS values, octaves and rounding.

15-minute lesson · Maths, power, electronics. In the app it ends with a three-level quiz and comes with the matching calculators.

Open the lesson

No need to be a maths whiz to tune a system, but you need a small toolkit: writing very big and very small numbers, turning a ratio into decibels, reading a sine wave, counting in octaves. With these you do most field maths in your head — and you know when the calculator is wrong… or when it’s you.

Powers of 10 and prefixes

PrefixSymbolFactorSound example
gigaG10⁹1 Gbit/s: a Dante network link
megaM10⁶1 MΩ: an active DI input
kilok10³48 kHz, 10 kΩ
millim10⁻³2 mV: a dynamic mic’s output; 20 ms of delay
microµ10⁻⁶20 µPa: hearing threshold; 1 µF
nanon10⁻⁹10 nF in a filter
picop10⁻¹²100 pF: roughly a metre of cable’s capacitance

Scientific notation, squares and roots

Write a number as a × 10ⁿ, with a between 1 and 10: 343 m/s = 3.43 × 10² m/s; 0.00002 Pa = 2 × 10⁻⁵ Pa. To multiply, add the exponents; to divide, subtract: 1 kΩ × 1 µF = 10³ × 10⁻⁶ = 10⁻³ s = 1 ms. On the calculator, the EXP (or ×10ˣ) key avoids zero-counting slips: 4.7 nF types as 4.7E-9. Squares: power goes with the square of voltage (P = U² / R), so doubling voltage quadruples power. Back to voltage with the root: 1000 W into 8 Ω needs U = √(1000 × 8) ≈ 89.4 V. Two roots to know: √2 ≈ 1.414 (sine peak and RMS) and √3 ≈ 1.732 (three-phase: 230 × √3 ≈ 400 V). In acoustics, intensity falls with the square of distance: the 1/r² law (see Propagation and SPL).

Logarithms: counting powers of 10

The base-10 logarithm answers “10 to what power?”: log(1000) = 3, log(1) = 0, log(0.01) = −2. It turns multiplications into additions: that’s why the decibel uses it, and why the ear — which hears ratios, not differences — feels at home (see The decibel, painlessly). Landmarks: log 2 ≈ 0.3, hence 10·log 2 ≈ 3 dB (power × 2) and 20·log 2 ≈ 6 dB (voltage × 2); log 3 ≈ 0.48; log 5 ≈ 0.7. To count octaves, use base-2 log: log₂(x) = log(x) / log(2) ≈ 3.32 × log(x). On a log scale, every octave takes equal space: that’s a spectrum analyser’s scale.

log(a × b) = log a + log b log(a / b) = log a − log b log(aⁿ) = n × log a log 2 ≈ 0.301

The sine: amplitude, period, phase

The sine is the base signal: a pure tone, the mains, a 1 kHz test signal. Its amplitude (peak, written Û) is its maximum excursion from zero. Its period T is one cycle’s duration, the inverse of frequency. One full cycle is one trip round a circle: 360°, i.e. 2π radians. Angular frequency ω = 2πf counts radians per second. A delay Δt shifts phase by 360 × f × Δt degrees: 1 ms at 250 Hz is a quarter-turn, 90° (see Frequency, wavelength, phase).

u(t) = Û · sin(ω·t + φ) ω = 2π·f T = 1 / f 180° = π rad φ = 360 × f × Δt

Peak, peak-to-peak, RMS

The RMS (root mean square) value is the DC voltage that would heat a resistor the same. For a sine only, RMS = peak / √2 ≈ 0.707 × peak, and peak-to-peak = 2 × peak. Mains 230 V is RMS: it actually peaks at 325 V, 650 V peak-to-peak. Crest factor compares peak to RMS. Careful: a bargain multimeter only reads right on a sine; on music or noise you need a “true RMS” meter.

SignalPeak / RMSCrest factor
Square10 dB
Sine√2 ≈ 1.413 dB
Triangle√3 ≈ 1.734.8 dB
Measurement pink noise≈ 4≈ 12 dB
Music4 to 1012 to 20 dB

Rule of three, octaves and rounding

Practise with

Sources

Continue