Système Dcalculate, tune, understand

Digital links and clocking

Wire AES3, S/PDIF, ADAT and MADI right, and grasp clocking: master, slaves, word clock, jitter and clicks.

15-minute lesson · Digital audio. In the app it ends with a three-level quiz and comes with the matching calculators.

Open the lesson

Between console and processor, remote preamp and interface, recorder and multitrack, sound often already travels digital. No added noise, no level loss: while the link works, it’s perfect. But when it fails, it isn’t a little hiss: clicks, dropouts, or nothing at all. Two things count: the right cable, and a shared clock.

AES3 (AES/EBU)

The reference pro link: two audio channels (up to 24-bit) on a balanced pair, over XLR. Signal runs a few volts; it also carries clock (biphase coding) and status data (rate, emphasis, etc.). The standard calls for 110 Ω cable and runs around 100 m. A mic cable works over metres, but its impedance is wrong: over distance it errors. An unbalanced 75 Ω BNC version exists (AES3-id), for longer hauls on video coax.

S/PDIF

AES3’s consumer sibling (IEC 60958): the same two channels, near-identical framing, but a lower level (~0.5 V) on 75 Ω coax with RCAs, or Toslink optical fibre. Built for ~10 m. Found on CD players, soundcards, some keys and hi-fi. A passive adaptor sometimes joins S/PDIF and AES3, but no promises.

ADAT (Lightpipe)

Born at Alesis for its tape machines, ADAT carries 8 channels at 44.1 or 48 kHz down one Toslink fibre. The classic way to bolt 8 preamps onto an interface. Higher up, S/MUX splits channels: 4 at 88.2/96 kHz, 2 at 192 kHz. So two ADAT ports at 96 kHz still give only 8 channels.

MADI (AES10)

Broadcast’s and big installs’ multichannel: up to 64 channels at 48 kHz (56 in the original), or 32 at 96 kHz, down one 75 Ω BNC coax or optical fibre. Coax stays within tens of metres; fibre spans long hauls (~2 km multimode). MADI doesn’t force the frame to clock anything: in practice, boxes often sync off a separate clock.

Clocking: one conductor only

Every digital box clocks its samples. Two boxes both set to “48 kHz internal” never run at exactly the same speed: their crystals differ by tens of parts per million (ppm). One ends up a sample over or short: the buffer overflows or starves, and clicks out, regularly. The rule: one master clock, every other box a slave — following clock embedded in the AES3, ADAT or MADI stream, a word-clock input, or the network.

Clock drift = fs × ppm gap 48,000 Hz × 50 ppm = 2.4 samples of drift per second

Word clock

Word clock is a square wave at sample rate, carried on 75 Ω coax with BNCs. Best is star distribution from a generator or multi-output distributor. If you daisy-chain boxes with BNC T-pieces, only the line’s last box takes a 75 Ω terminator; middle inputs must run high-impedance. Many boxes have a termination switch: check it. Two terminations halve signal and spawn reflections, and sync turns flaky.

Jitter

Jitter is wobble in clock-edge timing: a sample taken or rendered a shade early or late. It only bites at conversion (ADC, DAC), surfacing as noise and distortion. Between two digital boxes, while data lands error-free, link jitter can’t touch the numbers. Recent converters filter incoming-clock jitter. A “high-end” external clock serves syncing, not better conversion: a box’s internal clock is often the steadiest.

Latency and conversions

A digital link adds little delay — a handful of samples. Conversions cost: each analogue-then-digital round trip adds ADC/DAC filter latency, tenths of a millisecond to ~1 ms per model. An input SRC, letting in an unsynced source, adds its own latency too. Keep the chain digital end to end where possible. For networked audio (Dante, AES67, AVB) and PTP clocking, see Networks.

Sources

Continue

← Audio files and formats · Digital processing (DSP) →