Système Dcalculate, tune, understand

Blocking noise

Stopping sound travelling room to room: mass law, double walls, decoupling, leaks, Rw and DnT,w ratings, and what it means for a studio or concert hall.

15-minute lesson · Room acoustics. In the app it ends with a three-level quiz and comes with the matching calculators.

Open the lesson

Two trades get mixed up. Acoustic treatment works inside the room: reverb, reflections, what you hear. Isolation works between rooms: how many decibels reach the neighbours or enter your studio. Different materials. Absorbent foam does almost nothing for isolation; a concrete wall isolates well but throws everything back into the room. Even heavy absorbent treatment only drops reverberant level by 10·log(A₂ / A₁): doubling absorption is −3 dB, barely audible next door.

Two paths: airborne and structure-borne

Airborne noise shakes the wall, which radiates on the other side: voices, PA, guitar amp. Structure-borne noise enters the frame directly and travels through walls, slabs and beams, often far: dancing feet, kick drum on a riser, sub on the floor, AC bolted to the ceiling. Sound also flanks around the sides: a superb wall is useless if the slab runs underneath.

The mass law

R ≈ 20·log₁₀(m·f) − 47 dB (m in kg/m², f in Hz, single wall, diffuse field)

A single wall isolates better the heavier it is and the higher the frequency: +6 dB per doubling of surface mass, +6 dB per octave. A 10 kg/m² plasterboard gives ~27 dB at 500 Hz, a 20 cm concrete shell (460 kg/m²) ~60 dB. But at 63 Hz that same concrete only manages 42 dB: that’s PA bass waking the neighbours. Near its critical (coincidence) frequency, a wall loses isolation, as the panel’s bending wave locks onto the airborne wave. These values are theoretical; reality depends on workmanship.

Mass-spring-mass

Two walls split by an air gap (lining, double partition, double glazing) form a mass-spring-mass system. Below its resonant frequency f₀ it isolates no better than a single wall of equal mass; around f₀ it isolates even worse; above, isolation climbs far faster than mass law. So park f₀ well under the frequencies to stop: heavy walls and a wide air gap. Mineral wool in the cavity damps gap resonances: there it truly helps. Landmark: f₀ ≈ 60·√((1/m₁ + 1/m₂) / d), with m₁ and m₂ in kg/m² and d in m; two 10 kg/m² boards at 10 cm give ~85 Hz.

Decoupling

So the second wall isn’t shaken by the first, it mustn’t touch it. Independent studs, anti-vibration hangers for ceilings, pads or elastomer strips under a floating slab, soft joints all round. One screw joining both walls, a rigid pipe or a wedged plaster offcut builds a sound bridge and shorts part of the gain. Room-in-a-room takes the idea all the way: the fix for studios and demanding clubs — a complete inner room (floating floor, independent walls and ceiling) built inside the existing one, with zero rigid contact. Doors become lobbies with two heavy sealed doors. Ventilation runs through silencers and flexible ducts, electrics through sealed boxes. It’s pricey and eats space (often 20 to 40 cm per wall), but it’s the only way to strongly isolate bass.

Leaks

Sound takes the easiest path. If a small share of surface stands open, nearly all energy slips through: a 50 dB wall with 0.1% open falls to 30 dB, with 1% to 20 dB. Usual suspects: door bottoms, window seals, cable runs, ducts, back-to-back sockets, shared false ceilings. Maths runs in energy: each part passes τ = 10^(−R/10), area-weighted average, then overall R = −10·log₁₀(mean τ). One ajar fire door wipes out months of work: before blaming the wall, hunt the leak.

Ratings

RatingWhat it isWhere it’s measured
RwSingle-number reduction index of one wall (ISO 717-1)In the lab (ISO 10140)
R′wApparent reduction, flanking includedOn site
DnT,wLevel difference between two rooms, normalised to 0.5 s RT on the receiving side: what the neighbour livesOn site (ISO 16283-1)
C and CtrAdaptation terms: C for pink-like noise, Ctr for bass-rich noise (traffic, amplified music)Added to the rating: Rw + Ctr, DnT,w + C
L′nT,wImpact-noise level (standard tapping machine): lower is betterOn site

Studios and concert halls

Practise with

Sources

Continue

← The room · Microphones →